XMT-8 series digital temperature controller
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
▇ Model number and parameters
Model number | External dimensions | Perforation dimensions | Online store: |
XMTG-8 | 48x48x110 mm | 44 10x44 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMTE-8 | 48X96X110 mm | 44 10x92 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMTF-8 | 96x48x110 mm | 92 10x44 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMTD-8 | 72x72x110 mm | 68 10x68 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMTA-8 | 96x96x110 mm | 92 10x92 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMT-8 | 160x80x110 mm | 152 10x76 10 mm | US $39.99 - 56.69/ pieceOrder (24) |
XMT-8S | PC software | For RS485 type controller |
▇ General
Model number | XMT-8 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Input type | Thermocouple: K, J, S, B, E, N, T, WRe RTD: Pt100, Cu50 Voltage: 0-5V, 1-5V, 0-1V, 0-100mV, 0-20mV (Need to be customized, default don't have) Current: 0-20mA, 4-20mA, 0-10mA (Need to be customized, default don't have) |
Output type | Electromagnetic relay, SSR, current, triac (not in one product, need to be selected) |
Auxiliary function | Ramp/soak, communication (RS485 or RS232 interface) |
Power consumption | Less than 4W |
Control method | PID, or ON/OFF |
Setting method | Touch switch |
Indication method | 8-segment 4-digital display and LED indication |
Alarms | 1. Alarm quantity: XMTG-P: 1pcs, others: default is 1pcs, if 2pcs, need to be customized 2. Alarm form: ALM1: High limit alarm ALM2: Low limit alarm Hy-1: Positive deviation alarm Hy-2: Negative deviation alarm |
Sampling period | 0.5s |
Control period | Electromagnetic relay output: 2-120s (can adjust), others: 2s |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Operating humidity | 85% RH max, non-condensing |
Alias name | XMT-P series pid temperature controller, intelligent temperature controller |
▇ Output type and description
Electromagnetic relay | Contact rating: 5A at 220Vac |
Solid state relay | Contact rating can be selected, order separately (Single phase 40A, Three phase 40A) |
Current | Can be any value in 0-22mA |
Triac | Zero crossing pulse, Amplitude>3V, width>50us, the instrument's supply voltage and load must be same phase current |
▇ Auxiliary function
Ramp/soak | 30 segments program, can set up or down ramp Programming example: Rise to 50 degrees for 48 minutes Rise to 550 degrees for 120 minutes Rise to 980 degrees for 150 minutes Hold for 5 minutes and then stop C01=25, T01=48 C02=50, T02=120 C03=550,T03=150 C04=980,T04=5 C05=980,T05=-121 |
Communication | RS485 or RS232 interface (Standard Modbus RTU protocol, you need write the software yourself or buy the non-standard protocol contorller with PC software from us) |
▇ Input type and measuring range
K | -50-1300 ℃ (Bolt, Press spring, Ring, M12 probe, M8 probe, Flexible probe, Armor high temperature resistant, Customized thread probe) |
S | -50-1700 ℃ (Probe, Armor) |
B | 0-1800 ℃ |
E | 0-800 ℃ (Bolt, Press spring, Ring, Probe, Customized thread probe) |
N | 0-1300 ℃ |
T | -200-350 ℃ |
WRe | 0-2300 ℃ |
Pt100 | -199.9-649.0 ℃ (Bolt, Press spring, Ring, Probe, Polish rod, Polish rod waterproof, Polish rod waterproof anticorrosive, Flexible probe, Customized thread probe) |
Cu50 | -50-150 ℃ (Probe, Polish rod waterproof) |
Voltage 0-5V, 1-5V | 0.0-100.0 ℃ |
Current 0-20mA, 4-20mA | 0.0-100.0 ℃ |