Model number | REX-C series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 100-240VAC, 50/60 Hz |
Output type | Electromagnetic relay, SSR, current, SCR (not in one product, need to select) |
Control method | PID, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | REX-CH series |
Accuracy | ±0.5%FS±1℃ |
Supply voltage | REX-CH502: 220VAC, 50/60 Hz, other omdels: 100-240Vac, 50/60 Hz; |
Output type | Electromagnetic relay + SSR |
Control method | PID, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | CD-CH series |
Accuracy | RTD input: ±0.5%FS±1℃, Others input: ±1%FS±1℃ |
Supply voltage | 100-240Vac, 24Vac, 50/60 Hz; 24Vdc |
Output type | Electromagnetic relay, SSR, current, voltage, SCR (not in one product, need to select). Default is 1pcs, if 2pcs, need to be customized |
Control method | PID, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-3 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz; 24VAC/DC |
Output type | Electromagnetic relay, SSR (not in one product, need to select) |
Control method | PID, or ON/OFF, with time function |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-6 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Output type | Electromagnetic relay, SSR (not in one product, need to select) |
Auxiliary function | Time control |
Control method | PID, or ON/OFF, with time function |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-7 series |
Accuracy | RTD input: ±0.5%FS±1℃, Others input: ±1%FS±1℃ |
Supply voltage | 220Vac,110Vac 50/60 Hz; 12Vac/dc, 24Vac/dc |
Output type | Electromagnetic relay, SSR, current, voltage, triac (not in one product, need to select) |
Control method | PID, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-8 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Output type | Electromagnetic relay, SSR, current, triac (not in one product, need to be selected) |
Auxiliary function | Ramp/soak, communication (RS485 or RS232 interface) |
Control method | PID, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-JK2 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Output type | Electromagnetic relay, SSR, SCR, RS485 (not in one product, need to select) |
Control method | 2 PIDs, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-JK4 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Output type | Electromagnetic relay, SSR, SCR, RS485 (not in one product, need to select) |
Control method | 4 PIDs, or ON/OFF |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Model number | XMT-JK8 series |
Accuracy | ±0.5%F.S±1℃ |
Supply voltage | 85-242Vac,50/60 Hz |
Output type | Electromagnetic relay, SSR, SCR, RS485 (not in one product, need to select) |
Control method | 8 PIDs, or ON/OFF |