AI-518P digital temperature controller

Model number and parameters
Model numberExternal dimensionsPerforation dimensions
AI-518P-A96x96x100 mm92 10x92 10 mm
AI-518P-A296x96x100 mm92 10x92 10 mm
AI-518P-B160x80x100 mm152 10x76 10 mm
AI-518P-C80x160x100 mm76 10x152 10 mm
AI-518P-C380x160x100 mm76 10x152 10 mm
AI-518P-D72X72X95 mm68 10x68 10 mm
AI-518P-D248X48X95 mm45 10x45 10 mm
AI-518P-E48X96X100 mm45 10x92 10 mm
AI-518P-F96X48X100 mm92 10x45 10 mm
General
Model number AI-518P
Accuracy ±0.2% of full scale
Supply voltage 100~240VAC, -15%, 10% / 50~60Hz; 120-240VDC;
Input type Thermocouple: K, J, R, S, B, E, N, T, WRe3-WRe25, WRe5-WRe26
RTD: Pt100, Cu50
Voltage: 0-5V, 1-5V, 0-1V, 0-100mV, 0-20mV, 0-500mV
Current: 0-10mA, 0-20mA, 4-20mA
Expanded Remain above inputs, allow customer specify an input type (maybe need Indexing table).
Output type Modules: mechanical Relay, SSR, current, voltage, triac
Power consumption Less than 5 VA
Control method PID Control with auto-tuning and Self-tuning, or ON/OFF
Setting method Touch switch
Indication method 8-segment 4-digital display and LED indication
Alarms Upper limit, lower limit, deviation upper limit, deviation lower limit, may remove alarm when power on
Sampling period When set FILt=0, response time <=0.5s
Control period can be ajusted between 0.24 and 300.0s
Electromagnetic compatibility IEC61000-4-4 (Electrical fast transient burst), 4KV/5KHz; IEC61000-4-5 (Surge), 4kv
Isolation voltage >=2300v among power, relay contact and signal; >=600v between two isolated weak signal
Operating temperature 0 to 60 ℃ (32 to 140 ℉)
Operating humidity 90% RH max, non-condensing
Alias name AI-518P pid temperature controller, intelligent temperature controller
Output type and description
Electromagnetic relay Contact rating: 3A at 250Vac
Solid state relay Contact rating can be selected, order separately (Single phase 40AThree phase 40A)
Current 0-10mA or 4-20mA (Module, order separately)
Voltage 24V/12V/10V/5V DC (Module, order separately)
Triac Zero crossing pulse, phase-shift pulse (Module, order separately)
Input type and measuring range
K -50-1300 ℃ (BoltPress springRingM12 probeM8 probeFlexible probeArmor high temperature resistantCustomized thread probe)
R -50-1700 ℃
S -50-1700 ℃ (ProbeArmor)
B 200-1800 ℃
E 0-800 ℃ (BoltPress springRingProbeCustomized thread probe)
N 0-1300 ℃
T -200-350 ℃
WRe -20-2300 ℃
Pt100 -199.9-649.0 ℃ (BoltPress springRingProbePolish rodPolish rod waterproofPolish rod waterproof anticorrosiveFlexible probeCustomized thread probe)
Cu50 -50-150 ℃ (Probe)
Linear input -9990-30000