REX-C series digital temperature controller

Model number and parameters
Model numberExternal dimensionsPerforation dimensionsOnline store: 
REX-C10048x48x110 mm45 0.50x45 0.50 mmUS $7.16 - 9.74/ pieceOrder (11)
REX-C40048x96x110 mm45 0.50x92 0.50 mmUS $7.81 - 10.7/ pieceOrder (5)
REX-C41096x48x110 mm92 0.50x45 0.50 mmUS $7.81 - 10.25/ pieceOrder (5)
REX-C70072x72x110 mm68 0.50x68 0.50 mmUS $7.81 - 10.25/ pieceOrder (4)
REX-C90096x96x110 mm92 0.50x92 0.50 mmUS $7.81 - 10.25/ pieceOrder (4)
General
Model number REX-C series
Accuracy ±0.5%F.S±1℃
Supply voltage 100-240VAC, 50/60 Hz
Input type Thermocouple: K, J, R, S, B, E, N, T
RTD: Pt100, Cu50
Voltage: 0-5V, 1-5V (Need to be customized, default don't have)
Current: 0-20mA, 4-20mA (Need to be customized, default don't have)
REX-C100 has two types: only K input, Thermocouple and RTD input. Others are Thermocouple and RTD input.
If only K input type, the max temperature is 999°C, and don't have self-turning, LCK function
Output type Electromagnetic relay, SSR, current, SCR (not in one product, need to select)
Power consumption Less than 5VA
Control method PID, or ON/OFF
Setting method Touch switch
Indication method 8-segment 4-digital display and LED indication
Alarms 1. Alarm quantity: REX-C100: 1pcs, others: default is 1pcs, if 2pcs, need to be customized
2. Alarm form: N: No alarm
A: Deviation low
B: Deviation high
C: Deviation high/low
D: Band
E: Deviation high with hold action
F: Deviation low with hold action
G: Deviation high/low with hold action
H: Process high
J: Process low
K: Process high with hold action
L: Process low with hold action
Note: rex-c100 only K input just has Deviation high alarm.
Operating temperature 0 to 50 ℃ (32 to 122 ℉)
Operating humidity 30-85% RH max, non-condensing
Alias name REX-C pid temperature controller, intelligent temperature controller
Output type and description
Electromagnetic relay Contact rating: 3A at 250Vac
Solid state relay Contact rating can be selected, order separately (Single phase 40AThree phase 40A)
Current 4-20mA
Triac Zero crossing pulse
Input type and measuring range
K 0-1372 ℃ (BoltPress springRingM12 probeM8 probeFlexible probeArmor high temperature resistantCustomized thread probe)
R -50-1769 ℃
S 0-1769 ℃ (ProbeArmor)
B -50-1769 ℃
E 0-1000 ℃ (BoltPress springRingProbeCustomized thread probe)
N 0-1300 ℃
T -200-400 ℃
Pt100 -199.9-649.0 ℃ (BoltPress springRingProbePolish rodPolish rod waterproofPolish rod waterproof anticorrosiveFlexible probeCustomized thread probe)
Cu50 -50.0-150.0 ℃ (ProbePolish rod waterproof)
Voltage 0-5V, 1-5V 0.0-100.0 ℃
Current 0-20mA, 4-20mA 0.0-100.0 ℃