<
XMT-7 series digital temperature controller
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
▇ Model number and parameters
Model number | Same model | External dimensions | Perforation dimensions | Online store: |
XMTG-7 | XMTG-9 | 48x48x78 mm | 44 10x44 10 mm | US $13.79 - 17.28/ pieceOrder (19) |
XMTE-7 | XMTE-9 | 48x96x72 mm | 44 10x92 10 mm | US $13.79 - 18.45/ pieceOrder (11) |
XMTD-7 | XMTD-9 | 72x72x80 mm | 68 10x68 10 mm | US $13.79 - 17.28/ pieceOrder (10) |
XMTD2 | 72x72x80 mm | 68 10x68 10 mm | ||
XMTA-7 | XMTA-9 | 96x96x66 mm | 92 10x92 10 mm | US $13.79 - 17.28/ pieceOrder (10) |
XMT-7 | XMT-9 | 160x80x85 mm | 152 10x76 10 mm | US $16.12 - 19.61/ pieceOrder (10) |
▇ General
Model number | XMT-7 series |
Accuracy | RTD input: ±0.5%FS±1℃, Others input: ±1%FS±1℃ |
Supply voltage | 220Vac,110Vac 50/60 Hz; 12Vac/dc, 24Vac/dc |
Input type | Thermocouple: K, J, R, S, B, E, N, T RTD: Pt100, Cu50 Voltage: 0-5V, 1-5V Current: 0-20mA, 4-20mA (need connect a 250ohm resistance between thermocouple input terminals, if the resistance is built-in, will can't change it to thermocouple inputs) Note: 4-20mA input, 4-20mA output, the output has two types Transmit output (Just XMTD2 has): The output is relative to the input, if the display is 0-100 degree, eg: Input 4mA, Display 0, output 4mA Input 12mA, Display 50, Output 12mA Input 20mA, Display 100, Output 20mA PID output: The output value is relative to the main output set value, if the display is 0-100 degree, eg: Input 4mA, Display 0, output relative to the main output set value Input 12mA, Display 50, Output relative to the main output set value Input 20mA, Display 100, Output relative to the main output set value |
Output type | Electromagnetic relay, SSR, current, voltage, triac (not in one product, need to select) |
Power consumption | Less than 5 VA |
Control method | PID, or ON/OFF |
Setting method | Touch switch |
Indication method | 8-segment 4-digital display and LED indication |
Alarms | 1. Alarm quantity: XMTG: 1pcs, others: default is 1pcs, if 2pcs, need to be customized 2. Alarm form: N: No alarm A: Deviation high B: Deviation low C: Deviation high/low D: Band E: Deviation high with hold action F: Deviation low with hold action G: Deviation high/low with hold action H: Process high J: Process low K: Process high with hold action L: Process low with hold action P: Heater break (CTL-6), only AML1, when current output, don't have S: Heater break (CTL-12), only AML1, when current output, don't have R: Control loop break, either ALM1 or ALM2 XMTD2 alarm type: 00 no alarm 01 Measured value upper alarm 02 Measured value lower alarm 03 Deviation high 04 Deviation low 05 Deviation high/low 06 Band When the decade is 1, it is standby alarm state |
Operating temperature | 0 to 50 ℃ (32 to 122 ℉) |
Operating humidity | 85% RH max, non-condensing |
Alias name | XMT series pid temperature controller, intelligent temperature controller |
▇ Output type and description
Electromagnetic relay | Contact rating: 3A@250Vac, can make to 30A for XMTD, XMTA, XMT |
Solid state relay | Contact rating can be selected, order separately (Single phase 40A, Three phase 40A) |
Current | 4-20mA |
Voltage | 0-5V |
Triac | Zero crossing pulse (default); phase shift pluse (just XMTD2 has) |
▇ Input type and measuring range
K | 0-1372 ℃ (Bolt, Press spring, Ring, M12 probe, M8 probe, Flexible probe, Armor high temperature resistant, Customized thread probe) |
J | Ring |
R | -50-1769 ℃ |
S | 0-1769 ℃ (Probe, Armor) |
B | -50-1769 ℃ |
E | 0-1000 ℃ (Bolt, Press spring, Ring, Probe, Customized thread probe) |
N | 0-1300 ℃ |
T | -200-400 ℃ |
Pt100 | -199.9-649.0 ℃ (Bolt, Press spring, Ring, Probe, Polish rod, Polish rod waterproof, Polish rod waterproof anticorrosive, Flexible probe, Customized thread probe) |
Cu50 | -50.0-150.0 ℃ (Probe, Polish rod waterproof) |
Voltage 0-5V, 1-5V | 0.0-100.0 ℃ |
Current 0-20mA, 4-20mA | 0.0-100.0 ℃ |