Products >> Relays >> Solid state relays >> Single phase R-AC
<

Single phase resistance to AC solid state voltage regulator

Model number and parameters
Model numberLoad currentLoad voltageOnline store: 
SSR-10VA10A24-480VAC; 24-250VACUS $2.33 - 3.37/ pieceOrder (2)
SSR-25VA25A24-480VAC; 24-250VACUS $2.53 - 3.64/ pieceOrder (2)
SSR-40VA40A24-480VACUS $3.19/ pieceOrder
SSR-60VA60A24-480VACUS $4.69/ pieceOrder
SSR-75VA75A24-480VACUS $5.36/ pieceOrder
SSR-80VA80A24-480VACUS $5.7/ pieceOrder
SSR-100VA100A24-480VACUS $5.9/ pieceOrder
Suitable maximum load power
Load current (A) 10 25 40 60 75 80 100
220V resistive load power (KW) 1.1 2.8 4.4 6.6 8.3 8.8 11
220V inductive load power (KW) 0.4 0.8 1.3 1.9 2.4 2.6 3.2
General
Model number SSR-VA series
Rated input control voltage Variable resistor
Input resistance 470KΩ 2W potentiometer
Wattage of VR 1/4 W min
Pick-up or drop-out time 10ms max
Control type Phase control
Input-ON indication LED
On-state leakage current 2mA max
On-state voltage drop at Imax 1.5Vac
Matched heat sink ≤40A: FHSI01-50, ≤60A: FHSI02-50, ≤120A: FHSI03-100
Matched thermal grease HZ-KS101
Dielectric strength 2500VAC 50/60Hz for 1 minute
Insulation resistance 500 MΩ min at 500 VDC
External dimensions 62x45x23.5mm
Terminals Screw
Operational temperature -30 to 75℃
Operational humidity 95% max no condensation
Alias name SSR-VA series ingle phase resistance to AC solid state voltage regulator
Advantage
1. Special general circuit design for large current, high quality circuit board.
2. Use copper terminals for big current, increase the safety of connection and use.
3. Use pure aluminium base plate, with better performance and long life.
4. Hign-end flame-retardant PV plastic, thermostability can up to 70-80 degrees.
Note 1. Model selection method: calculate the load current, according to load type, multiply the balance factor.
Resistive load: balance factor is 2 times, such as incandescent lamp, resistance wire, oven, heating rod.
Inductive load: balance factor is 7 times, such as: transformer, coil, fan motor, pump motor.
Example: 220V 3KW resistive load. 3KW/220V*2=27.3, select 40A specification.

2. To use product long and safely, please install the product with corresponding heat sink and fan.
SSR series solid state relay drawing