▇ Model number and parameters
Model number | Load current | Load voltage | Online store: |
SSR-10VA | 10A | 24-480VAC; 24-250VAC | US $2.33 - 3.37/ pieceOrder (2) |
SSR-25VA | 25A | 24-480VAC; 24-250VAC | US $2.53 - 3.64/ pieceOrder (2) |
SSR-40VA | 40A | 24-480VAC | US $3.19/ pieceOrder |
SSR-60VA | 60A | 24-480VAC | US $4.69/ pieceOrder |
SSR-75VA | 75A | 24-480VAC | US $5.36/ pieceOrder |
SSR-80VA | 80A | 24-480VAC | US $5.7/ pieceOrder |
SSR-100VA | 100A | 24-480VAC | US $5.9/ pieceOrder |
▇ Suitable maximum load power
Load current (A) | 10 | 25 | 40 | 60 | 75 | 80 | 100 |
220V resistive load power (KW) | 1.1 | 2.8 | 4.4 | 6.6 | 8.3 | 8.8 | 11 |
220V inductive load power (KW) | 0.4 | 0.8 | 1.3 | 1.9 | 2.4 | 2.6 | 3.2 |
▇ General
Model number | SSR-VA series | ||||||||
Rated input control voltage | Variable resistor | ||||||||
Input resistance | 470KΩ 2W potentiometer | ||||||||
Wattage of VR | 1/4 W min | ||||||||
Pick-up or drop-out time | 10ms max | ||||||||
Control type | Phase control | ||||||||
Input-ON indication | LED | ||||||||
On-state leakage current | 2mA max | ||||||||
On-state voltage drop at Imax | 1.5Vac | ||||||||
Matched heat sink | ≤40A: FHSI01-50, ≤60A: FHSI02-50, ≤120A: FHSI03-100 | ||||||||
Matched thermal grease | HZ-KS101 | ||||||||
Dielectric strength | 2500VAC 50/60Hz for 1 minute | ||||||||
Insulation resistance | 500 MΩ min at 500 VDC | ||||||||
External dimensions | 62x45x23.5mm | ||||||||
Terminals | Screw | ||||||||
Operational temperature | -30 to 75℃ | ||||||||
Operational humidity | 95% max no condensation | ||||||||
Alias name | SSR-VA series ingle phase resistance to AC solid state voltage regulator | ||||||||
Advantage |
|
||||||||
Note | 1. Model selection method: calculate the load current, according to load type, multiply the balance factor. Resistive load: balance factor is 2 times, such as incandescent lamp, resistance wire, oven, heating rod. Inductive load: balance factor is 7 times, such as: transformer, coil, fan motor, pump motor. Example: 220V 3KW resistive load. 3KW/220V*2=27.3, select 40A specification. 2. To use product long and safely, please install the product with corresponding heat sink and fan. |
SSR series solid state relay drawing