H3-ZF-3 series three phase industrial grade solid state relay set
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
▇ Model number and parameters
Model number | Load current | Load voltage | Online store: |
H360ZF-3 | 60A | 24-480Vac | |
H380ZF-3 | 80A | 24-480Vac | |
H3100ZF-3 | 100A | 24-480Vac | US $69.83/ pieceOrder |
H3120ZF-3 | 120A | 24-480Vac | US $73.29/ pieceOrder |
H3150ZF-3 | 150A | 24-480Vac | US $80.97/ pieceOrder |
H3200ZF-3 | 200A | 24-480Vac | US $90.51/ pieceOrder |
H3300ZF-3 | 300A | 24-480Vac | US $109.34/ pieceOrder |
H3400ZF-3 | 400A | 24-480Vac | US $136.76/ pieceOrder |
H3600ZF-3 | 600A | 24-480Vac | US $269.51/ pieceOrder |
H31000ZF-3 | 1000A | 24-480Vac | US $427.63/ pieceOrder |
▇ Suitable maximum load power
Load current (A) | 60 | 80 | 100 | 120 | 150 | 200 | 300 | 400 | 600 | 1000 |
380V resistive load power (KW) | 11.4 | 15.2 | 19 | 22.8 | 28.5 | 38 | 57 | 76 | 114 | 190 |
380V inductive load power (KW) | 3.3 | 4.4 | 5.5 | 6.6 | 8.2 | 10.9 | 16.3 | 21.8 | 32.6 | 54.3 |
▇ General
Model number | H3-ZF-3 series |
Rated input control voltage | 3-32Vdc |
Rated input control current | 12mA |
Pick-up or drop-out time | 10ms max |
Control type | Zero crossing detection |
Input-ON indication | LED |
On-state leakage current | 4.5mA max |
On-state voltage drop at Imax | 1.6Vac |
Dielectric strength | 2500VAC 50/60Hz for 1 minute |
Insulation resistance | 500 MΩ min at 500 VDC |
External dimensions | 210x185x125 mm |
Terminals | Screw |
Operational temperature | -20 to 75℃ |
Operational humidity | 95% max no condensation |
Alias name | Three-phase industrial grade SSR set |
Note | 1. Model selection method: calculate the load current, according to load type, multiply the balance factor. Resistive load: balance factor is 2 times, such as incandescent lamp, resistance wire, oven, heating rod. Inductive load: balance factor is 7 times, such as: transformer, coil, fan motor, pump motor. Example: 9KW three phase 380V furnace. 9KW/380V*2=47.4, can select 60A specification. 2. Heat dissipation: note the ambient temperature, when is is too low, should warm it first then start up, if work in low temperature for long time, can increase the input current appropriatly; When the ambient temperature is too high, and tbe heat can not be dissipated effectively, should need more heat dissipation measure, make sure the SSR surface's tempearture less than 70 degrees Celsius; When work in high temperatures and different load for a long time, should increase the balance factor. |