Products >> Relays >> Solid state relays >> Three phase DC-AC
<

Three phase DC to AC solid state relays

Model number and parameters
Model numberSame modelLoad currentLoad voltageOnline store: 
TSR-10DAASH-3-DA481010A90-480VacUS $9.37/ pieceOrder
TSR-25DAASH-3-DA482525A90-480VacUS $10.11/ pieceOrder
TSR-40DAASH-3-DA484040A90-480VacUS $12.85/ pieceOrder
TSR-60DAASH-3-DA486060A90-480VacUS $17.74/ pieceOrder
TSR-80DAASH-3-DA488080A90-480VacUS $19.1/ pieceOrder
TSR-100DA-HASH-3-DA48100100A90-480VacUS $28.62/ pieceOrder
TSR-120DA-HASH-3-DA48120120A90-480VacUS $30.21/ pieceOrder
Suitable maximum load power
Load current (A) 10 25 40 60 80 100 120
380V resistive load power (KW) 1.9 4.8 7.6 11.4 15.2 19 22.8
380V inductive load power (KW) 0.6 1.4 2.2 3.3 4.4 5.5 6.6
General
Model number TSR-DA series
Rated input control voltage 3-32Vdc
Rated input control current 10-68mA
Pick-up voltage 3Vdc
Drop-out voltage 1Vdc
Pick-up or drop-out time 10ms max
Control type Zero crossing detection
Input-ON indication LED
On-state leakage current 2mA max
On-state voltage drop at Imax 1.5Vac
Matched heat sink ≤40A: FHSI04-105, ≤60A: FHSH01-110, ≤80A: FHSH01-150, ≤150A: FHSY01-110
Matched thermal grease HZ-KS101
Dielectric strength 1500VAC 50/60Hz for 1 minute
Insulation resistance 500 MΩ min at 500 VDC
External dimensions 105x74x33mm
Terminals Screw
Operational temperature -20 to 75℃
Operational humidity 95% max no condensation
Alias name TSR-DA series three phase DC to AC SSR
Advantage
1. The case is made of high quality PC and PVC, with good toughness, smooth appearance; HD transparent protective cover can protect the product better for use in a variety of environments.
2. Good heat dissipation: high quality thick aluminum base plate and relay are welded together seamlessly; plating process make the base plate smooth, so the SSR can be fit to heat sink better.
Note 1. Model selection method: calculate the load current, according to load type, multiply the balance factor.
Resistive load: balance factor is 2 times, such as incandescent lamp, resistance wire, oven, heating rod.
Inductive load: balance factor is 7 times, such as: transformer, coil, fan motor, pump motor.
Example: 9KW three phase 380V furnace. 9KW/380V*2=47.4, can select 60A specification.

2. Heat dissipation: note the ambient temperature, when is is too low, should warm it first then start up, if work in low temperature for long time, can increase the input current appropriatly; When the ambient temperature is too high, and tbe heat can not be dissipated effectively, should need more heat dissipation measure, make sure the SSR surface's tempearture less than 70 degrees Celsius; When work in high temperatures and different load for a long time, should increase the balance factor.
Three phase SSR drawing