S-600 series 600W general switching power supply

Model number and parameters
Model number S-600-5 S-600-12 S-600-15 S-600-24 S-600-36 S-600-48
Online store:  US $43.5/ pieceOrder US $43.5/ pieceOrder US $43.5/ pieceOrder US $43.5/ pieceOrder US $43.5/ pieceOrder US $43.5/ pieceOrder
DC output voltage 5V 12V 15V 24V 36V 48V
Output voltage error (Note: 2) ±0.5% ±1% ±1% ±1% ±1% ±1%
Rated output current 80A 50A 40A 25A 16.6A 12.5A
Output current rage 0-80A 0-50A 0-40A 0-25A 0-16.6A 0-12.5A
Wave and noise (Note: 3) 75mVp-p 120mVp-p 150mVp-p 240mVp-p 240mVp-p 240mVp-p
Inlets tability (Note: 4) ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
Load stability (Note: 5) ±0.5% ±1% ±1% ±1% ±1% ±1%
DC output power 400W 600W 600W 600W 600W 600W
Effciency 80% 83% 84% 86% 86% 87%
Adjustable range for DC voltage +10% +10% +10% +10% +10% +10%
General
Model number S-600 series
AC input voltage range 190-240VAC, 47-63Hz
Input current 5A/230V
AC inrush current Cold-start current: 46A/230V
Leakage current 3.5mA/240VAC max
Overload proctection 120%-150% Type:Foldback current limiting Rest:auto-recovery
Over-voltage protection 120%-150% Type:hiccup mode Rest:auto-recovery
High-temperature protection ERH3≥65℃-70℃ fan start, ≤55℃-60℃ fan close, ≥80℃-85℃, switch off output (5-15V)-(24-48V)
Temperature coefficient ±0.03%/℃ (0-50℃)
Setup rise hold up time 1s, 100ms, 50ms
Vibration 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes
Dielectric strength 1.5KVac, 50/60 Hz for 1 min between input and output
1.5KVac, 50/60 Hz for 1 min between input and enclosure
0.5KVac, 50/60 Hz for 1 min between output and enclosure
Isolation resistance 100MΩ min. at 500 VDC
Working temperature humidity -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH
Store temperature humidity -20℃-85℃, 10%-95%RH
External dimension 238x124x65 mm
Weight 1.4kg
Safety standards GB4949,UL60950,EN60950
EMC standards GB9254 EN55022 EN55024 A level
Note 1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH.
2. Error, include the setting error, line stability and load stability. (Note:5)
3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage
5. Load stability test: The load is from 0% to 100%.
S-600 series general switching power supply mounting dimensions