S-145 series 145W general switching power supply
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
Mouse over to zoom in
▇ Model number and parameters
Model number | S-145-5 | S-145-12 | S-145-15 | S-145-24 | S-145-36 | S-145-48 |
Online store: | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder |
DC output voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Output voltage error (Note: 2) | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
Rated output current | 25A | 12A | 9.6A | 6A | 4A | 3A |
Output current rage | 0-25A | 0-12A | 0-9.6A | 0-6A | 0-4A | 0-3A |
Wave and noise (Note: 3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlets tability (Note: 4) | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
Load stability (Note: 5) | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
DC output power | 125W | 144W | 144W | 144W | 144W | 144W |
Effciency | 78% | 80.5% | 81% | 83.5% | 83.5% | 83.5% |
Adjustable range for DC voltage | +10,-5% | +10% | +10% | +10% | +10% | +10% |
▇ General
Model number | S-145 series |
AC input voltage range | 88-132VAC/176-264VAC, selected by switch, 47-63Hz; |
Input current | 3.2A/115V, 1.6A/230V |
AC inrush current | Cold-start current: 30A/115V, 60A/230V |
Leakage current | 1mA/240VAC max |
Overload proctection | 105%-150% Type:Foldback current limiting Rest:auto-recovery |
Over-voltage protection | 115%-135% Type:hiccup mode Rest:auto-recovery |
Temperature coefficient | ±0.03%/℃ (0-50℃) |
Setup rise hold up time | 100ms, 50ms, 20ms |
Vibration | 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes |
Dielectric strength | 1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure |
Isolation resistance | 100MΩ min. at 500 VDC |
Working temperature humidity | -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH |
Store temperature humidity | -20℃-85℃, 10%-95%RH |
External dimension | 199x98x38 mm |
Weight | 0.7kg |
Safety standards | UL1950 TUV refer to 60950 |
EMC standards | CISPR22(refer to55022), IEC1000-4-2,3,4,IEC1000-3-2 |
Note | 1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH. 2. Error, include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage 5. Load stability test: The load is from 0% to 100%. |
S-145 series general switching power supply mounting dimensions