S-145-36 145W DC 36V 4A output AC 110V/220V input single group switching power supply

Product features
Mouse over to zoom in
S-145-36 145W DC 36V 4A output AC 110V/220V input single group switching power supply
Price: US $13.18 / piece
Model number: S-145-36
Product name: General switching power supply
Deliver to:
Shipping:
US $18.6via
Estimated Delivery Time: 9-15 days
Quantity:



Total price:US $31.78
Buy Now
Add to Cart
Inquire
Payment:
PayPal/Credit CardWESTERN UNIONBANK TRANSFER
Product description
Model number and parameters
Model number S-145-5 S-145-12 S-145-15 S-145-24 S-145-36 S-145-48
Online store:  US $13.18/ pieceOrder US $13.18/ pieceOrder US $13.18/ pieceOrder US $13.18/ pieceOrder Visiting... US $13.18/ pieceOrder
DC output voltage 5V 12V 15V 24V 36V 48V
Output voltage error (Note: 2) ±2% ±1% ±1% ±1% ±1% ±1%
Rated output current 25A 12A 9.6A 6A 4A 3A
Output current rage 0-25A 0-12A 0-9.6A 0-6A 0-4A 0-3A
Wave and noise (Note: 3) 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p
Inlets tability (Note: 4) ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
Load stability (Note: 5) ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
DC output power 125W 144W 144W 144W 144W 144W
Effciency 78% 80.5% 81% 83.5% 83.5% 83.5%
Adjustable range for DC voltage +10,-5% +10% +10% +10% +10% +10%
General
Model number S-145 series
AC input voltage range 88-132VAC/176-264VAC, selected by switch, 47-63Hz;
Input current 3.2A/115V, 1.6A/230V
AC inrush current Cold-start current: 30A/115V, 60A/230V
Leakage current 1mA/240VAC max
Overload proctection 105%-150% Type:Foldback current limiting Rest:auto-recovery
Over-voltage protection 115%-135% Type:hiccup mode Rest:auto-recovery
Temperature coefficient ±0.03%/℃ (0-50℃)
Setup rise hold up time 100ms, 50ms, 20ms
Vibration 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes
Dielectric strength 1.5KVac, 50/60 Hz for 1 min between input and output
1.5KVac, 50/60 Hz for 1 min between input and enclosure
0.5KVac, 50/60 Hz for 1 min between output and enclosure
Isolation resistance 100MΩ min. at 500 VDC
Working temperature humidity -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH
Store temperature humidity -20℃-85℃, 10%-95%RH
External dimension 199x98x38 mm
Weight 0.7kg
Safety standards UL1950 TUV refer to 60950
EMC standards CISPR22(refer to55022), IEC1000-4-2,3,4,IEC1000-3-2
Note 1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH.
2. Error, include the setting error, line stability and load stability. (Note:5)
3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage
5. Load stability test: The load is from 0% to 100%.