S-145-36 145W DC 36V 4A output AC 110V/220V input single group switching power supply
Product features
Mouse over to zoom in
S-145-36 145W DC 36V 4A output AC 110V/220V input single group switching power supply
Product description
▇ Model number and parameters
| Model number | S-145-5 | S-145-12 | S-145-15 | S-145-24 | S-145-36 | S-145-48 |
| Online store: | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder | US $13.18/ pieceOrder | Visiting... | US $13.18/ pieceOrder |
| DC output voltage | 5V | 12V | 15V | 24V | 36V | 48V |
| Output voltage error (Note: 2) | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
| Rated output current | 25A | 12A | 9.6A | 6A | 4A | 3A |
| Output current rage | 0-25A | 0-12A | 0-9.6A | 0-6A | 0-4A | 0-3A |
| Wave and noise (Note: 3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlets tability (Note: 4) | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
| Load stability (Note: 5) | ±0.5% | ±0.3% | ±0.3% | ±0.2% | ±0.2% | ±0.2% |
| DC output power | 125W | 144W | 144W | 144W | 144W | 144W |
| Effciency | 78% | 80.5% | 81% | 83.5% | 83.5% | 83.5% |
| Adjustable range for DC voltage | +10,-5% | +10% | +10% | +10% | +10% | +10% |
▇ General
| Model number | S-145 series |
| AC input voltage range | 88-132VAC/176-264VAC, selected by switch, 47-63Hz; |
| Input current | 3.2A/115V, 1.6A/230V |
| AC inrush current | Cold-start current: 30A/115V, 60A/230V |
| Leakage current | 1mA/240VAC max |
| Overload proctection | 105%-150% Type:Foldback current limiting Rest:auto-recovery |
| Over-voltage protection | 115%-135% Type:hiccup mode Rest:auto-recovery |
| Temperature coefficient | ±0.03%/℃ (0-50℃) |
| Setup rise hold up time | 100ms, 50ms, 20ms |
| Vibration | 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes |
| Dielectric strength | 1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure |
| Isolation resistance | 100MΩ min. at 500 VDC |
| Working temperature humidity | -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH |
| Store temperature humidity | -20℃-85℃, 10%-95%RH |
| External dimension | 199x98x38 mm |
| Weight | 0.7kg |
| Safety standards | UL1950 TUV refer to 60950 |
| EMC standards | CISPR22(refer to55022), IEC1000-4-2,3,4,IEC1000-3-2 |
| Note | 1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH. 2. Error, include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage 5. Load stability test: The load is from 0% to 100%. |
S-145 series general switching power supply mounting dimensions
Packaging Details
Product quantity: 1pc
Package weight: 0.8kg
Package size: 21 x 11 x 14 cm