▇ Model number and parameters
Model number | S-400-12 | S-400-15 | S-400-24 | S-400-36 | S-400-48 |
Online store: | US $23.28/ pieceOrder | US $23.28/ pieceOrder | US $23.28/ pieceOrder | US $23.28/ pieceOrder | US $23.28/ pieceOrder |
DC output voltage | 12V | 15V | 24V | 36V | 48V |
Output voltage error (Note: 2) | ±2% | ±2% | ±1% | ±1% | ±1% |
Rated output current | 33A | 26.6A | 16.6A | 11A | 8.3A |
Output current rage | 0-33A | 0-26.6A | 0-16.6A | 0-11A | 0-8.3A |
Wave and noise (Note: 3) | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p |
Inlets tability (Note: 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
Load stability (Note: 5) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
DC output power | 396W | 399W | 398W | 396W | 396W |
Effciency | 80% | 81% | 83% | 83% | 84% |
Adjustable range for DC voltage | +10% | +10% | +10% | +10% | +10% |
▇ General
Model number | S-400 series |
AC input voltage range | 90-132VAC/180-264VAC, selected by switch, 47-63Hz; 254-370VDC |
Input current | 6A/115V, 3A/230V |
AC inrush current | Cold-start current: 25A/115V, 50A/230V |
Leakage current | 3.5mA/240VAC max |
Overload proctection | 105%-150% Type:Foldback current limiting Rest:auto-recovery |
Over-voltage protection | 115%-135% Type:hiccup mode Rest:auto-recovery |
Temperature coefficient | ±0.03%/℃ (0-50℃) |
Setup rise hold up time | 200s, 100ms, 30ms |
Vibration | 10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes |
Dielectric strength | 1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure |
Isolation resistance | 100MΩ min. at 500 VDC |
Working temperature humidity | -10℃-60℃ (Refer to output characteristic figure), 20%-90%RH |
Store temperature humidity | -20℃-85℃, 10%-95%RH |
External dimension | 215x115x50 mm |
Weight | 1.15kg |
Safety standards | GB4949,UL60950,EN60950 |
EMC standards | GB9254 EN55022 EN55024 A level |
Note | 1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH. 2. Error, include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage 5. Load stability test: The load is from 0% to 100%. |