85-132VAC/170-264VAC, selected by switch, 47-63Hz; 240-370VDC
Input current
1.6A/115V, 0.8A/230V
AC inrush current
Cold-start current: 18A/115V, 36A/230V
Leakage current
0.5mA/240VAC max
Overload proctection
105%-150% Type:Foldback current limiting Rest:auto-recovery
Temperature coefficient
±0.03%/℃ (0-50℃)
Setup rise hold up time
200ms, 100ms, 30ms
Vibration
10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes
Dielectric strength
1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure
Isolation resistance
100MΩ min. at 500 VDC
Working temperature humidity
-10℃-60℃ (Refer to output characteristic figure), 20%-90%RH
Store temperature humidity
-20℃-85℃, 10%-95%RH
External dimension
157x97x38 mm
Weight
0.6kg
Safety standards
UL1012 (not apply to mark)
Note
1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH. 2. Error, include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage 5. Load stability test: The load is from 0% to 100%.
S-75 series general switching power supply mounting dimensions