S-60-12 usual 60W DC 12V 5A output AC 110V/220V input single group switching power supply
Product features
Mouse over to zoom in
S-60-12 usual 60W DC 12V 5A output AC 110V/220V input single group switching power supply
Price: US $4.58 / piece
Model number: S-60-12U
Product name: General switching power supplies
Deliver to:
Shipping:
US $15.87via
Estimated Delivery Time: 9-15 days
Quantity:
Total price:US $20.45
Buy Now
Add to Cart
Inquire
Payment:
PayPal/Credit CardWESTERN UNIONBANK TRANSFER
Product description
▇ Model number and parameters
Model number
S-60-5U
S-60-12U
S-60-15U
S-60-24U
Online store:
Visiting...
DC output voltage
5V
12V
15V
24V
Output voltage error (Note: 2)
±2%
±1%
±1%
±1%
Rated output current
12A
5A
4A
2.5A
Output current rage
0-12A
0-5A
0-4A
0-2.5A
Wave and noise (Note: 3)
100mVp-p
75mVp-p
75mVp-p
75mVp-p
Inlets tability (Note: 4)
±0.5%
±0.5%
±0.5%
±0.5%
Load stability (Note: 5)
±1%
±0.5%
±0.5%
±0.5%
DC output power
60W
60W
60W
60W
Effciency
73%
78%
78%
82%
Adjustable range for DC voltage
+10,-5%
+10%
+10%
+10%
▇ General
Model number
S-60 series
AC input voltage range
85-132VAC/170-264VAC, selected by switch, 47-63Hz; 240-370VDC
Input current
2A/115V, 1A/230V
AC inrush current
Cold-start current: 30A/115V, 60A/230V
Leakage current
3.5mA/240VAC max
Overload proctection
105%-150% Type:Foldback current limiting Rest:auto-recovery
Temperature coefficient
±0.03%/℃ (0-50℃)
Setup rise hold up time
800ms,50ms,10ms/150v,300ms,50ms,80ms/230v
Vibration
10-500HZ,2G 10min/1cycle, Periodfor 60min, Each axes
Dielectric strength
1.5KVac, 50/60 Hz for 1 min between input and output 1.5KVac, 50/60 Hz for 1 min between input and enclosure 0.5KVac, 50/60 Hz for 1 min between output and enclosure
Isolation resistance
100MΩ min. at 500 VDC
Working temperature humidity
-10℃-60℃ (Refer to output characteristic figure), 20%-90%RH
Store temperature humidity
-20℃-85℃, 10%-95%RH
External dimension
157x97x38 mm
Weight
0.55kg
Safety standards
UL1012 TUV refer to 6050 (IEC,UL1950) verification
EMC standards
CISPR22(refer to 55022), IEC801-2,3,4IEC555-2 verification
Note
1. The testing condition for the above paramenter is: 230VAC input, rated load, 25℃, Humidity 70%RH. 2. Error, include the setting error, line stability and load stability. (Note:5) 3. Wave test: adopting A12 double wire for 20MHZ,and 0.1uF-47uF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: when is over load,the lowest voltage of enter is representative to the highest voltage 5. Load stability test: The load is from 0% to 100%.