Product
<

D5M series inverter

D5M-1.5S2-1A inverter
Mouse over to zoom in
D5M-1.5S2-1A inverter
D5M-1.5S2-1A inverter
D5M-1.5S2-1A inverter
D5M-1.5S2-1A inverter
D5M-1.5S2-1A inverter
D5M-1.5S2-1A inverter
D5M-3.7S2-1A inverter
Mouse over to zoom in
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-3.7S2-1A inverter
D5M-1.5T4-1A inverter
Mouse over to zoom in
D5M-1.5T4-1A inverter
D5M-1.5T4-1A inverter
D5M-1.5T4-1A inverter
D5M-2.2T4-1A inverter
Mouse over to zoom in
D5M-2.2T4-1A inverter
D5M-2.2T4-1A inverter
D5M-2.2T4-1A inverter
D5M-11T4-1A inverter
Mouse over to zoom in
Model number and parameters
Model number Input voltage Power (KW) Drive capacity (KVA) Output current (A) Online store: 
D5M-0.4S2-1A 1PH 220V 50Hz 0.4 1 2.5 US $80.86 / pieceOrder
D5M-0.75S2-1A 1PH 220V 50Hz 0.75 2 5 US $85.35 / pieceOrder
D5M-1.5S2-1A 1PH 220V 50Hz 1.5 2.8 7 US $87.6 / pieceOrder
D5M-2.2S2-1A 1PH 220V 50Hz 2.2 4.4 11 US $110.05 / pieceOrder
D5M-3.7S2-1A 1PH 220V 50Hz 3.7 6.8 17 US $190.91 / pieceOrder
D5M-5.5S2-1A 1PH 220V 50Hz 5.5 10 25
D5M-0.4T4-1A 3PH 380V 50Hz 0.4 1.2 1.2 US $98.82 / pieceOrder
D5M-0.75T4-1A 3PH 380V 50Hz 0.75 2.2 2.7 US $101.07 / pieceOrder
D5M-1.5T4-1A 3PH 380V 50Hz 1.5 3.2 4 US $98.6 / pieceOrder
D5M-2.2T4-1A 3PH 380V 50Hz 2.2 4 5 US $114.55 / pieceOrder
D5M-3.7T4-1A 3PH 380V 50Hz 3.7 6.8 8.5 US $168.45 / pieceOrder
D5M-5.5T4-1A 3PH 380V 50Hz 5.5 10 12.5 US $190.91 / pieceOrder
D5M-7.5T4-1A 3PH 380V 50Hz 7.5 14 17.5 US $247.05 / pieceOrder
D5M-11T4-1A 3PH 380V 50Hz 11 19 24 US $404.27 / pieceOrder
D5M-15T4-1A 3PH 380V 50Hz 15 26 33 US $539.02 / pieceOrder
D5M-18.5T4-1A 3PH 380V 50Hz 18.5 32 40 US $651.32 / pieceOrder
General
Model number D5M series
Control method V/F curve
Input voltage 380V±15%; 220V±15%
Rated output voltage three phase 0-input voltage 0-400Hz
Indication method 4-digital display and LED indication, display frequency, current, revolution speed, voltage, counter, temperature, reversible state, failure, etc.
Communication control RS-485
Vibration <0.5G
Operating temperature -10 to 40 ℃
Operating humidity 95% RH max, non-condensing
Alias name D5M series AC Driver, Frequency Converter
Frequency Control
Range Digital: 0.01%(-10 to 40 ℃); Analog: 0.1%(25±10 ℃)
Setting Resolution Digital: 0.01Hz; Analog: maximum operating frequency of 1%
Output Resolution 0.01Hz
Keyboard settings mode Can set by ← ▲ ▼
Analog setting mode External voltage 0-5V, 0-10V, 4-20mA, 0-20mA
Other function Can set frequency lower limit, starting frequency, stopping frequency separately
General control
Acceleration and deceleration time 4 segment time (0.1-6500s) optionally
V/F curve Can be arbitrarily set V/F curve
Torque Control Torque boost can be set to a maximum of 10.0%, starting torque at 1.0Hz can be up to 150%
Multi-function input terminal 6 programmable inputs, to achieve 8 segment speed control, program run, 4 segment acceleration and deceleration switching, UP, DOWN function, counter, external emergency stop etc.
Multi-function output terminal 1 programmable output; to achieve operation, zero speed, counter, external error, program operation and other instructions and alarm.
Other function Automatic voltage regulation (AVR), deceleration stop or free-stop, DC braking, automatic reset and restart, frequency tracking, PLC program control, traverse control, draft control, automatic energy-saving operation, the carrier is adjustable (up to 20KHz) and the like.
Protective function
Overload Protection Electronic relay protection motor drive (constant torque 150%/1min, Fans type 120%/1min).0.01%(-10 to 40 ℃); Analog: 0.1%(25±10 ℃)
FUSE protection FUSE broken, the motor stops
Overvoltage 220V: DC voltage>390V; 380V: DC voltage>800V
Low voltage 220V: DC voltage>200V; 380V: DC voltage>400V
Instantaneous stop and restart Frequency can restart by tracking mode after momentary stop
Stall prevention Can prevente stall in acceleration or deceleration operation
Output short circuit Electronic circuit protection
Other function Fin overheat protection, reverse limit, directly start when power on, fault reset, parameter lock etc.